Polymeric insulated aerial bundled conductorsof rated voltage 0.6/1kV for overhead distribution( BS 7850)
The aerial bundled cables are designed for overhead distribution lines. All conductors made of aluminium 1350 and insulated with XLPE. Phase and neutral cores are laid up in a bundle with a left hand lay. It can be used for fixed installation as overhead power lines up to 1000V incl.
Construction
Conductor The conductors shall be of aluminium 1350 wires and are compacted circular stranded.
Insulation
XLPE. 1, 2 and 3 raised longitudinal ribs on the surface of the cores. The surface of the neutral core should have at least 12 ribs for cross-sections up to 50 mm^2 and a minimum of 16 ribs for cores above 50 mm^2. In the case of five core bundles the surface of the protective core should be smooth.
Assembly
2 up to 4 cores of equal cross section are stranded together in left-hand lay, additionally 1 or 2 cores of reduced cross section can be co-stranded.
No. |
Characteristic |
Units |
Nominal cross-sectional area of conductor |
|||||
25 |
35 |
50 |
70 |
95 |
120 |
|||
1 |
Nominal number of wire in conductor |
7 |
7 |
19 |
19 |
19 |
19 |
|
2 |
Conductor structure |
mm |
7/2.18 |
7/2.56 |
7/2.97 |
19/2.2 |
19/2.56 |
19/2.88 |
3 |
Form of conductors |
Stranded compacted circular |
||||||
4 |
Conductor direction |
Right direction |
||||||
5 |
Diameter of conductor |
mm mm |
5.6 |
6.6 |
7.7 |
9.3 |
11.0 |
12.5 |
6 |
Average conductor diameter |
mm |
5.9 |
7.0 |
8.3 |
10.0 |
11.6 |
13.0 |
7 |
Minimum average thickness of insulation |
mm |
1.3 |
1.3 |
1.5 |
1.5 |
1.7 |
1.7 |
8 |
Minimum thickness of insulation |
mm |
1.07 |
1.07 |
1.25 |
1.25 |
1.43 |
1.43 |
9 |
Maximum thickness of insulation |
mm mm |
2.1 |
2.1 |
2.1 |
2.1 |
2.1 |
2.1 |
10 |
Maximum diameter of core |
mm mm |
9.7 |
10.7 |
12.1 |
13.8 |
16.1 |
17.6 |
11 |
Neutral core identification |
12 |
12 |
12 |
16 |
16 |
16 |
|
12 |
Maxinmum d.c. resistance of conductor in bundle at 20℃ |
Ω/km |
1.200 |
0.868 |
0.641 |
0.443 |
0.320 |
0.253 |
13 |
Insulated wire core kilometre weight |
kg/km |
104 |
137 |
193 |
149 |
343 |
427 |
14 |
Ultimate tensile strength of conductor based on 170 |
kN |
4.1 |
5.6 |
7.6 |
11.0 |
15.3 |
19.4 |
http://www.laurence-group.com/
- Fashion Accessories
- Hair Products
- Jewelry
- Salon Equipment
- Candle & Candle Holders
- Christmas & Holiday
- Fireworks
- Greeting Cards
- Lighting Decoration
- Luminous & Fluorescent Items
- Bamboo Crafts
- Crystal Crafts
- Feather & Shell Crafts
- Glass Crafts
- Jade & Stone Crafts
- Lacquer Crafts
- Leather Crafts
- Metal Crafts